The future of flue gas analysis has arrived with the Testo 330 LL…
 

...and thanks to new instrument functions, now offers you even more professional and reliable support in regular tests and adjustment on your heating system.

Benefits of the new testo 330 LL:

 

Understand flue gas analysis at a glance...

 

Self-explanatory graphic curves as well as easy symbols and clear colour design ease the analysis of the measurement data for you considerably.

The central element of the new graphic processing of the measurement data is the flue gas matrix. In the course of the flue gas measurement, this shows you whether the CO and O 2 values, as well as other measurement parameters, are in the green, permitted range, and your heating system is thus optimally adjusted.

 

Thumb symbols instantly show you the status of the system. If the CO and O 2 concentrations measured are in the green range, the thumbs point up.
 

 

If the recorded measurement values are not within the optimum range, the flue gas matrix shows you important information for the required adjustment of the heating system.

Bad combustion – the CO concentration is over the defined limit value, the recorded CO content is not within the ideal range

Measurement value is not acceptable – the CO and
O 2 concentrations are considerably too high, the measurement values do not correspond to the prescribed norms and limit values

High loss – the O 2 concentration is over the defined limit value, the heating system is not working efficiently

Contact
Testo Ltd
Newman LaneAlton
GU34 2QJ Hampshire
United Kingdom

Telephone: 01420 544 433
Fax: 01420 544 434

E-Mail: info@testo.co.uk
www.testo.co.uk


The right measurement menu for every measurement task
 

Extended measurement menus offer you a comprehensive analysis of your heating system. The benefits of the new Testo 330 LL in the various measurement tasks are illustrated by these 5 typical measurement menus:


 

  Flue gas measurement…
The gas pipe test…
The draught measurement…
The ambient CO measurement...
The differential pressure measurement ΔP...
 

Flue gas measurement…


 

is the central measurement in flue gas analysis. By determining the main values, CO and O 2 , as well as other measurement parameters, a judgement can be made as to whether your heating system is properly adjusted or whether there is a need for optimisation. Different display options offer the right presentation of the measurement values, depending on requirements:

  • 4- to 8-line as numerical values
  • 4 measurement values simultaneously presented in a line graph
  • Main values O 2 und CO, as well as other measurement parameters, presented graphically as a flue gas matrix


 


Benefits of the new flue gas matrix:  

  • The flue gas matrix acts as an adjustment assistant for the main values O 2 and CO
  • The optimisation of the adjustment is much easier – interpretation of the numerical values is no longer necessary
  • Thanks to the trend display, the measurement curve can be followed exactly, and the measurement point precisely determined.
  • The automatic zoom function provides an enlarged and clear display of the current detail of the flue gas matrix
 

>  See the view of the instrument display here

 

>  See ordering suggestion here!

The gas pipe test…


 

is divided into 4 measurements which guarantee a comprehensive test of the gas pipe: The gas tightness test, usability test, gas fitting tightness test and leakage detection. After selecting the desired measurement, the Testo 330 LL begins directly with the corresponding gas pipe check. A separate gas leak detection probe is required for leakage detection. The gas tightness test can be conducted over a period of 10 minutes. The gas fitting tightness test is conducted over a period of one minute directly under operating conditions.
 


 


Benefits of the new Testo 330 LL: 

  • Thanks to prescribed measurement procedures, the desired test can be conducted quickly and easily
  • The Testo 330 LL leads the user through the measurement step by step, presenting the corresponding information in the display
  • The measurement data are displayed in easy and clear diagrams
 

>  See the view of the instrument display here

 

>  See ordering suggestion here!

The draught measurement…


 

begins directly after the selection of the corresponding measurement menu. After the zeroing of the pressure sensor, the determination of the differential pressure between the surroundings and the flue takes place. 
 


 


Benefits of the new Testo 330 LL:

  • Graphically supported measurement menu for the determination of the flue draught with parallel core flow search
  • Thanks to the integrated switchover valve technology, the testo 330-2 LL can remain in the flue during zeroing. In the testo 330-1 LL, the probe must be removed from the flue for zeroing
  • The set alarm threshold will be shown directly on the display
 

>  See the view of the instrument display here

 

>  See ordering suggestion here!

The ambient CO measurement...


 

determines the CO concentration in the ambient air. The measurement is presented in a simple graph. If the CO concentration is in the green range, the recorded concentration is permitted and the alarm threshold is not exceeded. The red danger range indicates a too high, not permitted CO concentration.
 


 


Benefits of the new testo 330 LL: 

  • Easy, graphic presentation of the adjustable alarm thresholds
  • With the help of the trend display, the measurement curve can be followed
  • The cursor marks the current CO concentration
  • The instrument not only indicates the violation of the alarm threshold optically, it also provides an audible alarm
 

>  See the view of the instrument display here

 

>  See ordering suggestion here!

The differential pressure measurement ΔP…


 

takes place after selection of the measurement menu "Differential pressure". After setting up the pressure difference required for the measurement, the measurement curve can be followed directly in the display over a defined period.
 


 


Benefits of the new Testo 330 LL: 

  • The measurement curve of the differential pressure measurement can be followed directly in the line diagram
  • Using the logger function, the measurement curve can be recorded over a defined period of up to 120 minutes
 

>  See the view of the instrument display here

 

>  See ordering suggestion here!

Contact
Testo Ltd
Newman LaneAlton
GU34 2QJ Hampshire
United Kingdom

Telephone: 01420 544 433
Fax: 01420 544 434

E-Mail: info@testo.co.uk
www.testo.co.uk


Choose one of the ordering suggestions with the Testo 330 LL Flue Gas analyser or testo 327 now!


Only valid from 01.09. to 31.12.2010

Illustration may differ from original

Ordering suggestion 1

Testo 330-1 LL Professional Set for the Domestic Installer and Heating Engineer with Printer
 

  • Testo 330-1 LL Flue gas Analyser (O 2 and COH 2 ) incl. rech. battery and calibration protocol
  • 100-240 V mains unit for mains operation or charging the rechargeable battery in the instrument
  • Carry case
  • Flue gas probe length 180 mm x 6mm diameter 
  • Fast printer with wireless infrared interface
  • Pack of 6 paper rolls
Illustration may differ from original

Ordering suggestion 2

Testo 330-2 LL Professional Set for the Commercial Installer and Service Engineer with Printer 
 

  • Testo 330-2 LL Flue Gas Analyser  (O 2 and COH 2 ) rech. battery and calibration protocol
  • 100-240 V mains unit for mains operation or charging the rechargeable battery in the instrument
  • Fast printer with wireless infrared interface
  • 6 printer rolls
  • Carry case
  • Flue gas probe length 300 mm, Ø 8 mm, Tmax. 500 °C


     

Illustration may differ from original

Ordering suggestion 3

Testo 327-1 Advanced Kit

  • Testo 327-1 flue gas analyser incl. rech. batteries and calibration protocol
  • Mains unit 100-240 V for mains operation or battery charging the in instrument
  • Compact flue gas probe, 180 mm long, ø 6 mm
  • Combustion air temperature probe, immersion depth 190 mm
  • Fast Printer with wireless infrared interface
  • Basic system case for instrument, probes and accessories
       
 
Illustration may differ from original

Ordering suggestion 4

Testo 327-2 Bluetooth Advanced Kit 
 

  • Testo 327-2 Flue Gas Analyser  incl. Bluetooth, rech. battery and calibration protocol
  • Mains unit 100-240 V for mains operation or battery charging the in instrument
  • Flue gas probe, 180 x 6mm diameter
  • Combustion air temperature probe, immersion depth 190 mm
  • Fast printer with wireless infrared interface
  • Basic system case for instrument, probes and accessories


     

 
Contact
Testo Ltd
Newman LaneAlton
GU34 2QJ Hampshire
United Kingdom

Telephone: 01420 544 433
Fax: 01420 544 434

E-Mail: info@testo.co.uk
www.testo.co.uk


Take advantage of the benefits of the new Testo 330 LL Flue Gas Analyser?
 

Then enter your personal data here, so that we can contact you, or if you wish, send you our product brochure for the new testo 330 LL.

Following data are missing

    Your Data:

     
     
     
     
    /
    /
     
    /
    /
     
     
     
     
     
    Please call me
     
    Product brochure testo 330 LL
    Find more details on the new flue gas analyzer testo 330 LL here
     
     
    Please supply me with a quotation
     
    Yes, I herewith agree to receiving the free newsletter. The free newsletters will be sent to the e-mail address given by me, so that I am always informed about the newest offers in the future. I am aware that I can stop receiving the newsletters at any time, using a de-registration link, without any costs being incurred to me.
     
     
    * Mandatory fields
    Contact
    Testo Ltd
    Newman LaneAlton
    GU34 2QJ Hampshire
    United Kingdom

    Telephone: 01420 544 433
    Fax: 01420 544 434

    E-Mail: info@testo.co.uk
    www.testo.co.uk


    Technical data of the Testo 330 LL Flue Gas Analyser

     

    Temperature

    Measurement range

    Accuracy

     

    Resolution

    -40 to +1200 °C

    ±0.5 °C (0.0 to +100.0 °C)
    ±0.5 % of mv (remaining range)

    0.1 °C (-40 to 999.9 °C)
    1 °C (remaining range)

    Draught measurement

    Measurement range
    Accuracy
    (the greater value applies)


    Resolution

    -9.99 to +40 hPa
    ±0.02 hPa or ±5% of mv (-0.50 to +0.60 hPa)
    ±0.03 hPa (+0.61 to +3.00 hPa)
    ±1.5% of mv (+3.01 to +40.00 hPa)

    0.01 hPa

    Pressure measurement

    Measurement range
    Accuracy


     

    Resolution

    0 to 300 hPa
    ±0.5 hPa (0.0 to 50.0 hPa)
    ±1% of mv (50.1 to 100.0 hPa)
    ±1.5 % of mv (remaining range)
    0.1 hPa

    O 2 measurement

    Measurement range
    Resolution
    Accuracy
    Adjustment time t 90

    0 to 21 Vol. %
    0.1 Vol. %
    ±0.2 Vol. %
    < 20 sec

    CO measurement
    (without H 2 compensation)
     

    Measurement range
    Resolution
    Accuracy



    Adjustment time t 90

    0 to 4000 ppm
    1 ppm
    ±20 ppm (0 to 400 ppm)
    ±5% of mv (401 to 1000 ppm)
    ±10% of mv (1001 to 4000 ppm)
    < 60 sec

    CO measurement
    (H 2 compensated))
     



    from 8000 ppm

    Measurement range
    Resolution
    Accuracy

     


    Adjustment time t 90
    Display area
    Resolution

    0 to 8000 ppm
    1 ppm
    ±10 ppm or ±10% of mv (0 to 200 ppm)
    ±20 ppm or ±5% of mv (201 to 2000 ppm)
    ±10% of mv (2001 to 8000 ppm) 
     < 60 sec
    8000 to 30.000 ppm (automatic dilution)
    500 ppm

    Efficiency
    (ETA)

    Measurement range
    Resolution

    0 to 120%
    0.1%

    Flue gas loss

    Measurement range
    Resolution

    0 to 99.9%
    0.1%

    CO 2 measurement

    Display range


    Resolution
    Accuracy
    Measurement


    Adjustment time t 90

    0 to CO 2 max
     

    0.1 Vol. %
    ±0.2 Vol. %
    Digital calculation from O 2

    < 40 sec

    Option: CO low measurement

    Measurement range
    Resolution
    Accuracy

     

    Adjustment time t 90

    0 to 500 ppm
    0.1 ppm
    ±2 ppm (0.0 to 40.0 ppm)
    ±5% of mv (remaining range)  

    < 30 sec

    Option: NO measurement

    Measurement range
    Resolution
    Accuracy

     


    Adjustment time t 90

    0 to 3000 ppm
    1 ppm
    ±5 ppm (0 to 100 ppm)
    ±5% of mv (101 to 2000 ppm)
    ±10% of mv (2001 to 3000 ppm)
    < 30 sec

    Ambient CO measure-
    ment (with CO probe)

    Measurement range
    Resolution
    Accuracy


    Adjustment time t 90

    0 to 500 ppm
    1 ppm
    ±5 ppm (0 to 100 ppm)
    ±5% of mv (>100 ppm)
    Approx. 35 sec

    Gas leak measurement
    for combustible gases
    (with gas leak detection
    probe)
     

    Range of indication
    Signal

      

    Adjustment time t 90

    0 to 10.000 ppm CH 4 / C 3H 8
    Optical display (LED)
    audible display via buzzer
    < 2 sec.

    Ambient CO 2 measure-
    ment (with ambient CO 2
    probe)

    Measurement range

     

    Accuracy
    Adjustment time t 90

    0 to 1 Vol. %
    0 to 10.000 ppm
    ±(50 ppm ±2% of mv) (0 to 5000 ppm)
    Approx. 35 sec

    General Technical Data
     

    Memory
    Weight
    Dimensions
    Storage temperature
    Operating temperature
    Display

    Power supply

    500.000 readings
    600 g (without rechargeable battery)
    270 x 90 x 65 mm
    -20 to +50 °C
    -5 to +45 °C
    Colour graphic display
    with 240 x 320 Pixel
    Rechargeable battery pack 3.7 V
    2.6 Ah Mains unit 6 V / 1.2 A

    Warranty

    Instrument/probe/
    gas sensors (O 2, CO)

    NO-, CO low sensor


    Thermocouple and
    rechargeable battery

    48 months


     

    24 months

     

    12 months

     
    Contact
    Testo Ltd
    Newman LaneAlton
    GU34 2QJ Hampshire
    United Kingdom

    Telephone: 01420 544 433
    Fax: 01420 544 434

    E-Mail: info@testo.co.uk
    www.testo.co.uk


    Further benefits of the new Testo 330 LL Flue Gas Analyser:

    The sensors – long life with even more security
     

    • Extended lifetime of the O 2 and CO sensors reduces service costs, and at least one sensor replacement is saved during the average working lifetime
    • Testo gives a warranty of 5 years on the complete instrument testo 330 LL (incl. O 2 and CO sensors and probe)*
     

    The sensor diagnosis

     
    • SensordiagnoseEasy and reliable testing of the sensor status in the sensor diagnosis menu
    • The result of the sensor diagnosis is symbolised by a traffic light




     

    * Exception: Wearing parts such as filter, thermocouple (12 months), NO/COlow sensor (24 months)


    Easy and mobile data management – adapted to your communication needs
     

    • The new Testo 330 LL communicates not only with a PC, but with a Pocket PC too – depending on your individual communication needs
    • The PC software easyheat allows the administration of your customer data, measurement sites as well as past measurement – conveniently at home on a PC
    • The Pocket PC software easyheat.mobile supports wireless communication with Windows mobile devices – and thus allows the direct wireless recording of measurement data on site
    • With the help of the IrDA/Bluetooth printer, the data can be printed out directly from the Pocket PC or measuring instrument
    • IrDa/Bluetooth interface for fast and secure data transfer to Pocket-PC / laptop / printer
    • USB interface for data readout to PC software

    The probes – the right accessories for every application
     

    • The Testo 330 LL has a fast probe connection – meaning all gas paths are connected, and incorrect connections are eliminated
    • The robust and easy-to-hold probe handle makes positioning the probe easier
    • Exchanging the probe is extremely easy – the correct probe shaft is placed on the probe handle and engages
    • Different probe lengths and diameters offer high flexibility – multi-hole and dual wall clearance probes complete the flue gas probe range
    • The ambient CO probe, the CO 2 probe as well as the gas leak probe are automatically recognized by the measuring instrument – apart from this, these probes have an alarm threshold, which, when exceeded, trigger an audible alarm
    • Gas tightness measurement is integrated in the new testo 330 LL – by connecting the new pressure set for gas tightness testing, the testo 330 LL allows the tightness of the gas line to be tested – without a separate measuring instrument

    Contact
    Testo Ltd
    Newman LaneAlton
    GU34 2QJ Hampshire
    United Kingdom

    Telephone: 01420 544 433
    Fax: 01420 544 434

    E-Mail: info@testo.co.uk
    www.testo.co.uk