testo 174T
Temperature logger
> More information
|
1 x internal |
NTC |
-22 to +158 °F (-30 to +70 °C) |
 |
- Temperature monitoring
- Cold chain monitoring (storage and transport)
- Food sector (complies with EN 12830)
|
|
|
testo 174H
Temperature and
humidity data logger
> More information
|
2 x internal |
NTC / capacitive humidity sensor |
-4 to +158 °F (-20 to +70 °C) internal 0 to 100 %RH |
|
- Temperature and humidity monitoring
- Use in commercial storage rooms
|
|
|
testo 175 T1
Temperature logger
> More information
|
1 x internal |
NTC |
-31 to +131°F (-35 to +55 °C) internal |
 |
- Cold chain monitoring
- Documentation of refrigerted and deep-freeze room temperatures
- Food sector (complies with EN 12830)
|
|
|
testo 175 T2
Temperature logger
> More information
|
1 x internal 1 x external |
NTC |
-31 to +131°C ( -35 to +55) internal -40 to +248 °F (-40 to +120 °C) external |
 |
- Simultaneous measure-
ment of ambient and product temperatures - Core temp. measurement of the goods
- Food sector (complies with EN 12830)
|
|
|
testo 175 T3
Temperature logger
> More information
|
2 x external |
Thermocouple (Type T and Type K) |
-58 to +752 °F (Type T) -58 to +1832 °F (Type K) |
|
- Parallel documentation
at two temperature measurement sites - Monitoring heating or refrigeration systems
|
|
|
testo 175 H1
Temperature and humidity data logger
> More information
|
2 x internal (stump) |
NTC / capacitive humidity sensor |
-4 to +131 °F -40 to +122 °Ftd 0 to 100 %RH |
|
- Monitoring ambient conditions
- Long-term monitoring in work and storage rooms
|
|
|
testo 176 T1
Temperature logger in metal housing
> More information
|
1 x internal |
Pt100 |
-31 to +158 °F (-35 to +70 °C ) |
 |
- Highly accurate temp. measurement under extreme conditions
- Very rugged thanks to metal housing
- Food sector (complies with EN 12830)
|
|
|
testo 176 T2
Temperature logger with connections for highly accurate external sensor
> More information
|
2 x external |
Pt100 |
-58 to +752 °F (-50 to +400 °C) |
 |
- Highly accurate measure-
ment in pharmaceutical surroundings - Simultaneous measure-
ment at two measurement sites - Food sector (complies with EN 12830)
|
|
|
testo 176 T3
Temperature data logger in metal housing
> More information
|
4 x external |
Thermocouple (Type T, Type K and Type J) |
-328 to +752 °F (Type T) -319 to +1832 °F (Type K) -148 to +1382°F (Type J) |
|
- Parallel temperature measurement at four sites
- Various applications thanks to external probe connections
- Very rugged thanks to metal housing
|
|
|
testo 176 T4
Temperature logger
> More information
|
4 x external |
Thermocouple (Type T, Type K and Type J) |
-328 to +752 °F (Type T) -310 to +1832 °F (Type K) -148 to +1382 °F (Type J) |
|
- Flow and return temperature testing on an underfloor heating system
- Simultaneous measurement at four sites
- Various applications thanks to external probe connections
|
|
|
testo 176 H1
Temperature and humidity data logger
> More information
|
2 probes 4 external channels |
NTC / capacitive humidity sensor |
-4 to +158 °F -40 to +158 °Ftd 0 to 100 %RH |
|
- Temperature and humidity monitoring
- Use in work and storage rooms
- Parallel measurement at two sites
|
|
|
testo 176 H2
Temperature and humidity data logger in metal housing
> More information
|
2 probes 4 external channels |
NTC / capacitive humidity sensor |
-4 to +158 °F -40 to +158 °Ftd 0 to 100 %RH |
|
- Documentation of values in ventilation systems
- Connection of different external humidity probes
- Very rugged thanks to metal housing
|
|
|
testo 176 P1
Pressure, temperature and humidity data logger
> More information
|
1 x internal 2 probes 4 external channels |
NTC / capacitive humidity sensor / absolute pressure sensor |
-4 to +158 °F -40 to +158 °Ftd 0 to 100 %RH 8.7 to 15.9 psi (600 to 1100 mbar) |
|
- Highly accurate documentation of ambient conditions
- Use in pharmaceutical laboratories
- Connection of up to two external humidity probes
|
|